Public demo snapshot of an in-house pyRevit extension for precast concrete shop-ticket QC (37 checks / 46 checklist rows) and a standalone panel handling solver (PCI Chapter 8). - No client, job, plant or product data: knowledge layers ship as structural templates only. - Ticket QC's model-read escalation targets a LAN model server endpoint (configurable), not a cloud provider. - Built from the private development repo via tools/make_dist.py.
571 lines
19 KiB
YAML
571 lines
19 KiB
YAML
# ============================================================================
|
|
# knowledge/catalogue.yaml -- DISTRIBUTION CARVE-OUT, not the real file
|
|
# ============================================================================
|
|
# Written by tools/make_dist.py's build_catalogue_carveout(), which reads
|
|
# the owner's real knowledge/catalogue.yaml and re-emits ONLY the branches
|
|
# below -- parsed and re-dumped from the real file, never hand-typed, so
|
|
# this cannot drift out of step with what the real file actually publishes.
|
|
# The real file itself never leaves the private checkout. See
|
|
# knowledge/README.md and CONTRIBUTING.md for the full accounting.
|
|
#
|
|
# SHIPPED, AND WHY EACH PIECE IS SAFE TO:
|
|
#
|
|
# face_designations trade abbreviations (N.F., F.F., T.I.F., ...)
|
|
# printed on shop tickets everywhere. The real file's
|
|
# own header already calls this branch public --
|
|
# identifies no client, job, or plant.
|
|
# orientation.up_end a fact about precast assemblies IN GENERAL (which
|
|
# Revit axis is "up" once an assembly's origin is
|
|
# correctly configured), not one plant's naming
|
|
# convention -- the owner's own ruling for keeping it
|
|
# in the public layer rather than a plant file.
|
|
# catalogue.rebar ASTM A706 / A615 grade tables -- a published
|
|
# national standard, not a manufacturer's rating.
|
|
# catalogue.safety_factors both null, by design -- see the note inline.
|
|
# checklist.master the shop-ticket QC checklist's SKELETON: row ids,
|
|
# names, grades, and which check function answers
|
|
# each one. This tool's own built-in configuration,
|
|
# not knowledge about any job -- identifies nobody.
|
|
#
|
|
# NOT SHIPPED:
|
|
#
|
|
# catalogue.inserts real lifting-insert capacities (ALP catalog,
|
|
# 02/2024), cited to a page and a date. EMPTY here.
|
|
# catalogue.slotted_inserts real JVI slotted-insert capacities. Omitted
|
|
# entirely (nothing in this distribution's
|
|
# tests needs its structure present at all).
|
|
# connectors.products real sandwich-wall tie capacities. EMPTY here.
|
|
#
|
|
# A handful of tests read those omitted tables directly and assert the
|
|
# owner's real published numbers. They are excluded from this
|
|
# distribution's test run, by name, with that reason -- see
|
|
# tools/make_dist.py's append_test_exclusions() and CONTRIBUTING.md.
|
|
# ============================================================================
|
|
|
|
face_designations:
|
|
frames:
|
|
view:
|
|
means: Relative to the viewing direction of the drawing. It flips when the view flips, so resolving
|
|
one of these tokens requires knowing which way the elevation looks at the piece.
|
|
sides:
|
|
- near
|
|
- far
|
|
- both
|
|
form:
|
|
means: Relative to the casting bed -- how the piece lies while it is poured. Absolute for the piece;
|
|
a flipped view does not change it.
|
|
sides:
|
|
- top
|
|
- bottom
|
|
- side
|
|
- both
|
|
vocabularies:
|
|
near_far:
|
|
frame: view
|
|
measured_from: the direction the elevation looks at the piece
|
|
tokens:
|
|
- token: N.F.
|
|
means: near face
|
|
side: near
|
|
- token: F.F.
|
|
means: far face
|
|
side: far
|
|
- token: E.L.
|
|
means: each layer
|
|
side: both
|
|
in_form:
|
|
frame: form
|
|
measured_from: the casting bed the piece is poured on
|
|
tokens:
|
|
- token: T.I.F.
|
|
means: top in form
|
|
side: top
|
|
- token: B.I.F.
|
|
means: bottom in form
|
|
side: bottom
|
|
- token: S.I.F.
|
|
means: side in form
|
|
side: side
|
|
orientation:
|
|
up_end:
|
|
source: assembly_origin
|
|
also_called: TOT
|
|
stated_by: Will
|
|
stated_on: '2026-08-30'
|
|
means: Which end of a precast piece is up once it is erected is a property of the assembly's origin,
|
|
which is placed with the assembly and carries an up end. It is not derived from where the piece
|
|
happens to sit in the model, and it is not a producer's convention.
|
|
origin_up: BasisY
|
|
origin_up_as_stated: '"assembly origin 里面有一个朝上的头" -- the assembly origin itself carries an up end.'
|
|
origin_up_verified: true
|
|
origin_up_verified_by: the bridge holder, against 282 assemblies
|
|
origin_up_verified_on: '2026-08-30'
|
|
also_seen_as:
|
|
horizontal_panels:
|
|
stated_by: Will
|
|
stated_on: '2026-08-30'
|
|
status: confirmed against 282 assemblies -- see origin_up above
|
|
green:
|
|
axis: BasisY
|
|
means: the erected up direction
|
|
purple:
|
|
axis: BasisZ
|
|
means: top-in-form
|
|
red:
|
|
axis: BasisX
|
|
means: the long direction
|
|
note: The API exposes no colour at all; this three-arrow mapping is a reading of the owner's words
|
|
(green / purple / red), and it is CONFIRMED because the measurement behind origin_up above --
|
|
BasisY exactly global (0,0,1) on 281 of 282 assemblies, BasisZ the smallest extent on 25 of
|
|
26 sampled, BasisX the longest on 23 of 26 -- is the same measurement that stands the colours
|
|
up.
|
|
vertical_wall_panels:
|
|
stated_by: Will
|
|
stated_on: '2026-09-01'
|
|
status: ONE of three arrows confirmed. Do not treat this frame as complete and do not borrow purple
|
|
or red from horizontal_panels above -- the owner's own words are that the arrows are different
|
|
between the two frames to begin with, so nothing here may be assumed from there.
|
|
green:
|
|
axis: BasisY
|
|
means: world up (world Z+) when the panel is correctly configured
|
|
confirmed: true
|
|
stated_as: '"vertical wall panel里面,世界的上方应该是绿色箭头" -- in a vertical wall panel, world up should
|
|
be the green arrow.'
|
|
purple:
|
|
axis: null
|
|
means: null
|
|
confirmed: false
|
|
open_question: Not yet stated. A vertical wall panel's casting orientation (top-in-form) is
|
|
not necessarily on the same axis as a horizontal panel's -- do not infer BasisZ here. Asked
|
|
of the owner 2026-09-01; record the answer here, cited and dated, the day it arrives.
|
|
red:
|
|
axis: null
|
|
means: null
|
|
confirmed: false
|
|
open_question: Not yet stated. Do not infer BasisX (the horizontal frame's "long direction")
|
|
here -- on a vertical wall panel BasisY already carries a different meaning (world up) from
|
|
the horizontal frame's (erected up when stood on end), so nothing about red follows from the
|
|
horizontal row either. Asked of the owner 2026-09-01; record the answer here, cited and dated,
|
|
the day it arrives.
|
|
applies_to: horizontal_panels
|
|
up_tolerance: 0.99
|
|
near_square_ratio: 1.25
|
|
declines_because: A piece whose origin does not agree with its geometry, a vertical panel whose frame
|
|
nobody has explained yet, and a near-square piece that could be either are three different reasons
|
|
to have no answer. All three are answers; none of them is a default.
|
|
wp401_2026_09_01: 'WP401 is NOT an instance of applies_to declining -- it never reaches that third
|
|
check. Its measured basis_up is (0, 1, 0), so up_end_from_origin()''s FIRST refusal (the up basis
|
|
must actually be world up, within up_tolerance) fires before up_axis or applies_to are ever read;
|
|
the report''s fallback-to-global-elevation notice on WP401 is that first refusal, not the third.
|
|
Under the green-arrow rule above (vertical_wall_panels), a correctly configured vertical wall panel''s
|
|
BasisY IS world up -- so WP401''s (0, 1, 0) is a real defect on that assembly''s origin (TOT), not
|
|
merely an unconfirmed frame; the report''s red line follows from this fact, not from applies_to.
|
|
Consequence for the code, worked out and not acted on: widening applies_to to admit vertical_wall_panels
|
|
would NOT change WP401''s verdict -- refusal #1 still fires first on it regardless. It WOULD change
|
|
any piece whose origin genuinely has BasisY at world up AND whose up_axis is not ''width'': such
|
|
a piece currently declines at refusal #3 (fallback to global elevation, disclosed) and would start
|
|
being read off the origin instead (the ruled mechanism, undisclosed because it is no longer a fallback).
|
|
No such piece has been surveyed. That survey, and the decision whether to widen applies_to on the
|
|
strength of it, is the owner''s, not made here.'
|
|
origin_point_meaning: null
|
|
origin_point_unverified_because: Nobody has measured where Transform.Origin sits relative to the piece,
|
|
and nobody has asked whether the owner's "up end" means the point or the direction. Until one of
|
|
those happens the point is not read at all.
|
|
catalogue:
|
|
safety_factors:
|
|
tension_fos: null
|
|
shear_fos: null
|
|
unknown_because: There is no trade-wide safety factor on a lifting insert to publish here. A factor
|
|
belongs to the part that was tested, so it is written inside each `inserts:` entry against the page
|
|
that publishes it. The 2.67 that used to sit here had no source and the manufacturer's own page
|
|
gives 4:1 in shear for the parts it covers; see the block above. A part with no entry of its own
|
|
is NOT judged on an ultimate rating -- it is named as unjudged, because inheriting one manufacturer's
|
|
factor is exactly the failure this null exists to prevent.
|
|
inserts: {}
|
|
rebar:
|
|
stock_length_ft: 40.0
|
|
astm_grades:
|
|
A706:
|
|
grades_ksi:
|
|
- 60
|
|
- 80
|
|
default_fy_ksi: 60
|
|
default_declared_by: Will
|
|
default_declared_on: '2026-08-30'
|
|
note: Grade 60 is the default, not the definition -- A706 Grade 80 exists.
|
|
A615:
|
|
grades_ksi:
|
|
- 60
|
|
- 80
|
|
- 100
|
|
default_fy_ksi: null
|
|
note: the designation alone does not give a grade -- ask, do not assume.
|
|
connectors:
|
|
what_it_is: The part that crosses the insulation of a sandwich (insulated) wall panel and ties the two
|
|
concrete wythes together. Declared by the owner 2026-08-31.
|
|
products: {}
|
|
checklist:
|
|
master:
|
|
- id: '1.1'
|
|
name: Sheet name equals the piece mark
|
|
grade: A
|
|
owner_codes:
|
|
- SHEET-NAME
|
|
not_run_reason: null
|
|
checks: check_sheet_name
|
|
- id: '1.2'
|
|
name: Sheet design-number reduces to the piece design
|
|
grade: A
|
|
owner_codes:
|
|
- DSN-MATCH
|
|
- DSN-SUFFIX
|
|
- DSN-PREFIX
|
|
not_run_reason: null
|
|
checks: null
|
|
- id: '1.3'
|
|
name: Exactly one ticket set per piece
|
|
grade: A
|
|
owner_codes:
|
|
- TICKET-SET
|
|
not_run_reason: null
|
|
checks: check_ticket_set
|
|
- id: '1.4'
|
|
name: Every placed view name refers to this design
|
|
grade: B
|
|
owner_codes:
|
|
- VIEW-DSN
|
|
not_run_reason: null
|
|
checks: check_view_name_design
|
|
- id: '1.5'
|
|
name: Printed call-outs do not overlap each other
|
|
grade: C
|
|
owner_codes:
|
|
- CALLOUT-OVERLAP
|
|
not_run_reason: null
|
|
checks: check_callout_overlap
|
|
- id: '2.1'
|
|
name: Printed length/width/depth vs modelled
|
|
grade: B
|
|
owner_codes:
|
|
- SIZE-LENGTH
|
|
- SIZE-WIDTH
|
|
- SIZE-MAX-
|
|
- SIZE-MIN-
|
|
not_run_reason: null
|
|
checks: null
|
|
- id: '2.2'
|
|
name: Weight three ways agree, and which one is odd is named
|
|
grade: A
|
|
owner_codes:
|
|
- WGT-
|
|
not_run_reason: null
|
|
checks: check_weight_three_way
|
|
- id: '2.3'
|
|
name: Unit weight ticket vs design summary
|
|
grade: A
|
|
owner_codes:
|
|
- PCF-NOTE
|
|
- PCF-MODEL
|
|
not_run_reason: null
|
|
checks: null
|
|
- id: '2.4'
|
|
name: Cast extras (a ledge is its own family) counted in the weight
|
|
grade: A
|
|
owner_codes:
|
|
- CAST-EXTRA
|
|
not_run_reason: null
|
|
checks: check_cast_extras
|
|
- id: '3.1'
|
|
name: f'c ticket vs summary
|
|
grade: A
|
|
owner_codes:
|
|
- FC
|
|
not_run_reason: null
|
|
checks: null
|
|
- id: '3.2'
|
|
name: f'ci ticket vs summary
|
|
grade: A
|
|
owner_codes:
|
|
- FCI
|
|
not_run_reason: null
|
|
checks: null
|
|
- id: '3.3'
|
|
name: f'ci/f'c release ratio in band
|
|
grade: B
|
|
owner_codes:
|
|
- FCI-RATIO
|
|
not_run_reason: null
|
|
checks: check_release_ratio
|
|
- id: '4.1'
|
|
name: Printed strand count vs modelled
|
|
grade: B
|
|
owner_codes:
|
|
- STR-QTY
|
|
not_run_reason: null
|
|
checks: null
|
|
- id: '4.2'
|
|
name: Strand diameter & grade vs design
|
|
grade: A
|
|
owner_codes:
|
|
- STR-DIA
|
|
- STR-DIA-EXTRA
|
|
not_run_reason: null
|
|
checks: null
|
|
- id: '4.3'
|
|
name: Jacking force on ticket vs design
|
|
grade: A
|
|
owner_codes:
|
|
- JACK-FORCE
|
|
not_run_reason: null
|
|
checks: check_jacking_force
|
|
- id: '4.4'
|
|
name: Strand positions vs design chain from stated rail
|
|
grade: B
|
|
owner_codes:
|
|
- STRAND-POS
|
|
not_run_reason: null
|
|
checks: check_strand_layout
|
|
- id: '4.5'
|
|
name: Debonded strands called out where the design debonds
|
|
grade: C
|
|
owner_codes:
|
|
- STRAND-CALLOUT
|
|
not_run_reason: null
|
|
checks: check_debond_callout
|
|
- id: '4.6'
|
|
name: Row count & spacing plausible
|
|
grade: A
|
|
owner_codes:
|
|
- STRAND-SPACING
|
|
- STRAND-ROWS
|
|
- STRAND-GRID
|
|
- BED-WIDTH
|
|
- BED-OFFSET
|
|
not_run_reason: null
|
|
checks: check_strand_layout
|
|
- id: '4.7'
|
|
name: Strand debonded wherever the concrete runs short
|
|
grade: B
|
|
owner_codes:
|
|
- STRAND-DEBOND
|
|
not_run_reason: null
|
|
checks: check_strand_debond
|
|
- id: '4.8'
|
|
name: BOM strand row agrees with the section print and the model
|
|
grade: A
|
|
owner_codes:
|
|
- BOM-STRAND
|
|
not_run_reason: null
|
|
checks: check_bom_strand_count
|
|
- id: '5.1'
|
|
name: BED PLAN callout embed exists in model
|
|
grade: A
|
|
owner_codes:
|
|
- BOM-MEMBERS
|
|
- DETAIL-CALLOUT
|
|
not_run_reason: null
|
|
checks:
|
|
- check_bom_members
|
|
- check_detail_callouts
|
|
- id: '5.2'
|
|
name: Embed in model appears on ticket
|
|
grade: A
|
|
owner_codes:
|
|
- BED-REVERSE
|
|
not_run_reason: null
|
|
checks: check_bed_plan_reverse
|
|
- id: '5.3'
|
|
name: Face designations consistent with model side
|
|
grade: C
|
|
owner_codes: null
|
|
not_run_reason: 'grade C: a person reads the face designations against the model side -- by design
|
|
no check computes this row, so it is a prompt to look and never a verdict'
|
|
checks: null
|
|
- id: '5.4'
|
|
name: Mesh / WWF designation vs design
|
|
grade: A
|
|
owner_codes:
|
|
- WWF
|
|
not_run_reason: null
|
|
checks: check_wwf_designation
|
|
- id: '5.5'
|
|
name: Bar marks legible on the drawing
|
|
grade: D
|
|
owner_codes: null
|
|
not_run_reason: 'grade D: a person reads the drawing; code only guarantees the question was asked'
|
|
checks: null
|
|
- id: '5.6'
|
|
name: Bar marks unique, and model and print name the same bars
|
|
grade: B
|
|
owner_codes:
|
|
- BARMARK-UNIQUE
|
|
not_run_reason: null
|
|
checks: check_bar_mark_uniqueness
|
|
- id: '5.7'
|
|
name: No bar longer than the stock it is cut from
|
|
grade: B
|
|
owner_codes:
|
|
- BAR-LENGTH
|
|
not_run_reason: null
|
|
checks: check_bar_stock_length
|
|
- id: '5.8'
|
|
name: Connectors present on an insulated panel
|
|
grade: B
|
|
owner_codes:
|
|
- CONNECTOR-EXIST
|
|
not_run_reason: null
|
|
checks: check_connectors_exist
|
|
- id: '5.9'
|
|
name: Enough connectors for what the design calls for
|
|
grade: B
|
|
owner_codes:
|
|
- CONNECTOR-COUNT
|
|
not_run_reason: null
|
|
checks: check_connectors_sufficient
|
|
- id: '5.10'
|
|
name: Connector edge distances
|
|
grade: B
|
|
owner_codes:
|
|
- CONNECTOR-EDGE
|
|
not_run_reason: null
|
|
checks: check_connector_edge_distance
|
|
- id: '5.11'
|
|
name: Every lifter's solid zone is a member of the assembly
|
|
grade: B
|
|
owner_codes:
|
|
- SOLID-ZONE-ASM
|
|
- SOLID-ZONE-ABSENT
|
|
not_run_reason: null
|
|
checks: check_solid_zone_members
|
|
- id: '5.12'
|
|
name: Solid zones appear on the ticket's insulation layout
|
|
grade: B
|
|
owner_codes:
|
|
- SOLID-ZONE-TICKET
|
|
not_run_reason: null
|
|
checks: check_solid_zone_on_ticket
|
|
- id: '5.13'
|
|
name: Solid zone hatch matches the legend swatch
|
|
grade: B
|
|
owner_codes:
|
|
- SOLID-ZONE-HATCH
|
|
not_run_reason: null
|
|
checks: check_solid_zone_hatch
|
|
- id: '5.14'
|
|
name: Insulation recess regions present where the design calls for them
|
|
grade: C
|
|
owner_codes:
|
|
- RECESS-PRESENT
|
|
not_run_reason: null
|
|
checks: check_recess_regions
|
|
- id: '5.15'
|
|
name: Recess region hatch matches the legend swatch
|
|
grade: B
|
|
owner_codes:
|
|
- RECESS-HATCH
|
|
not_run_reason: null
|
|
checks: check_recess_hatch
|
|
- id: '6.1'
|
|
name: Insert capacity vs load
|
|
grade: A
|
|
owner_codes:
|
|
- LIFT-CAPACITY
|
|
not_run_reason: null
|
|
checks: check_lifter_capacity
|
|
- id: '6.2'
|
|
name: Insert edge distances
|
|
grade: A
|
|
owner_codes:
|
|
- LIFT-EDGE
|
|
not_run_reason: null
|
|
checks: check_lifter_edge_distance
|
|
- id: '6.3'
|
|
name: Current handling result exists & passes
|
|
grade: A
|
|
owner_codes:
|
|
- HANDLE-
|
|
not_run_reason: null
|
|
checks: check_handling_result
|
|
- id: '6.4'
|
|
name: Dunnage not under an opening
|
|
grade: A
|
|
owner_codes:
|
|
- DUN-OPENING
|
|
not_run_reason: null
|
|
checks: check_dunnage_openings
|
|
- id: '6.5'
|
|
name: DUNNAGE / ERECTION / PICKING notes say something
|
|
grade: B
|
|
owner_codes:
|
|
- NOTE-CONTENT
|
|
not_run_reason: null
|
|
checks: check_note_views
|
|
- id: '6.6'
|
|
name: Odd part count carries the BED PLAN note it requires
|
|
grade: B
|
|
owner_codes:
|
|
- PARITY-NOTE
|
|
not_run_reason: null
|
|
checks: check_parity_note
|
|
- id: '6.7'
|
|
name: Minimum spacing between lifting anchors
|
|
grade: A
|
|
owner_codes:
|
|
- LIFT-SPACING
|
|
not_run_reason: null
|
|
checks: check_lifter_anchor_spacing
|
|
- id: '6.8'
|
|
name: Printed picking stations match the modelled picking inserts
|
|
grade: B
|
|
owner_codes:
|
|
- PICK-STATIONS
|
|
- PICK-UNREADABLE
|
|
not_run_reason: null
|
|
checks: check_picking_match
|
|
- id: '6.9'
|
|
name: Lifting-point count vs panel length (MC)
|
|
grade: A
|
|
owner_codes:
|
|
- LIFT-POINTS
|
|
- LIFT-POINTS-UNREAD
|
|
not_run_reason: null
|
|
checks: check_lifting_points
|
|
- id: '6.10'
|
|
name: Lifting-point position vs PCI recommendation (MC)
|
|
grade: A
|
|
owner_codes:
|
|
- LIFT-POS
|
|
- LIFT-POS-UNREAD
|
|
not_run_reason: null
|
|
checks: check_lift_positions
|
|
- id: '6.11'
|
|
name: Dunnage-point count vs stripping-point count (MC)
|
|
grade: A
|
|
owner_codes:
|
|
- DUN-STRIP
|
|
- DUN-STRIP-UNREAD
|
|
not_run_reason: null
|
|
checks: check_dunnage_stripping_match
|
|
- id: '7.1'
|
|
name: Interference check
|
|
grade: B
|
|
owner_codes:
|
|
- CLASH
|
|
- CLASH-UNREADABLE
|
|
not_run_reason: null
|
|
checks: check_member_interference
|
|
- id: '8.1'
|
|
name: No unresolved design-summary lines
|
|
grade: C
|
|
owner_codes:
|
|
- SPEC-UNRESOLVED
|
|
not_run_reason: null
|
|
checks: check_spec_unresolved
|
|
- id: '8.2'
|
|
name: No invisible characters in ticket text
|
|
grade: A
|
|
owner_codes:
|
|
- INVISIBLE
|
|
not_run_reason: null
|
|
checks: check_invisible
|